Motor Circuit Breakers
Filters
Motor circuit breaker, TeSys GV2, 3P, 9-14 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 14A/690V, for 3-phase motor applications 5.5kW@400V. It provides a thermal-magnetic protection with a...
View full detailsMotor circuit breaker, TeSys GV2, 3P, 6-10 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 10A/690V, for 3-phase motor applications 3-4kW@400V. It provides a thermal-magnetic protection with a...
View full detailsExtended rotary handle kit, TeSys GV2, IP54, red handle, with trip indication, for GV2L-GV2P
Schneider ElectricTeSys GV extended rotary handle, for motor circuit breakers GV2L, GV2P mounted inside an enclosure and to be operated externally. For emergency swi...
View full detailsExtended rotary handle kit, TeSys GV2, IP54, black handle, with trip indication, for GV2L-GV2P
Schneider ElectricTeSys GV extended rotary handle, for motor circuit breakers GV2L, GV2P mounted inside an enclosure and to be operated externally. For main switch u...
View full detailsGV2P10 - Motor Circuit breaker, TeSys GV2, 3P, 4-6.3 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 6.3A/690V, for 3-phase motor applications 2.2kW@400V. It provides a thermal-magnetic protection with ...
View full detailsMotor circuit breaker, TeSys GV2, 3P, 2.5-4 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 4A/690V, for 3-phase motor applications 1.1-1.5kW@400V. It provides a thermal-magnetic protection wit...
View full detailsMotor circuit breaker, TeSys GV2, 3P, 1.6-2.5 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 2.5A/690V, for 3-phase motor applications 0.75kW@400V. It provides a thermal-magnetic protection with...
View full detailsMotor circuit breaker, TeSys GV2, 3P, 1-1.6 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 1.6A/690V, for 3-phase motor applications 0.37-0.55kW@400V. It provides a thermal-magnetic protection...
View full detailsMotor circuit breaker, TeSys GV2, 3P, 0.63-1 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for 3-phase motor applications 0.25kW@400V. It provides a thermal-magnetic protection with a...
View full detailsMotor circuit breaker, TeSys GV2, 3P, 0.4-0.63 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 0.63A/690V, for 3-phase motor applications 0.12-0.18kW@400V. It provides a thermal-magnetic protectio...
View full detailsMotor circuit breaker, TeSys GV2, 3P, 0.25-0.4 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 0.4A/690V, for 3-phase motor applications 0.09kW@400V. It provides a thermal-magnetic protection with...
View full detailsMotor circuit breaker, TeSys GV2, 3P, 0.16-0.25 A, thermal magnetic, screw clamp terminals
Schneider ElectricTeSys GV motor circuit breaker, 3 poles (3P), 0.25A/690V, for 3-phase motor applications 0.06kW@400V. It provides a thermal-magnetic protection wit...
View full detailsTeSys GV3 - auxiliary contact block - 1 NO + 1 NC
Schneider ElectricTeSys Deca auxiliary contact block, for contactors LC1D, LC1F and control relays CAD. It provides 1NO+1NC contacts rated up to 10A 690V AC, On-dela...
View full detailsShunt release (MX), TeSys GV2-GV3, 220-240V AC 50Hz
Schneider ElectricTeSys GV electrical trip, MX shunt release, 220-240V AC 50Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control vo...
View full detailsShunt release (MX), TeSys GV2-GV3, 110-115V AC 50Hz
Schneider ElectricTeSys GV electrical trip, MX shunt release, 110-115V AC 50Hz / 127V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when...
View full detailsTeSys GV2 & GV3, auxiliary contact, 1 NO + 1 NC (fault)
Schneider ElectricTeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NC fault signaling contact + 1NO instantaneous auxiliary contact. Instan...
View full detailsTeSys GV2 - Enclosure for TeSys GV2ME - IP55
Schneider ElectricTeSys enclosed starters, empty enclosure, for thermal magnetic circuit breakers GV2ME. Surface mounting enclosure with screw fixing, 2 knock-outs f...
View full detailsTeSys GV2 - Flush mounting enclosure for TeSys GV2ME - IP55
Schneider ElectricTeSys enclosed starters, empty enclosure, for thermal magnetic circuit breakers GV2ME. Flush mounting enclosure, sealable cover. Polycarbonate encl...
View full detailsTeSys GV2 - Enclosure for TeSys GV2ME - IP41
Schneider ElectricTeSys enclosed starters, empty enclosure, for thermal magnetic circuit breakers GV2ME. Surface mounting enclosure with screw fixing, 2 knock-outs f...
View full detailsTeSys GV2 - Combination blocks - with LAD311 and contactor LC1D09...D38
Schneider ElectricTeSys GV accessory, combination block for motor starter assembly. For the connection between a motor circuit breaker GV2 or a fuse carrier LS1D32 a...
View full detailsTeSys GV2 - Combination blocks - with contactor LC1D09...D38
Schneider ElectricTeSys GV accessory, combination block for motor starter assembly. For the connection between a motor circuit breaker GV2 or a fuse carrier LS1D32 a...
View full detailsTeSys GV2 & GV3 - auxiliary contact block - 2 NO
Schneider ElectricTeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 2NO instantaneous auxiliary contacts. Rated for operation up to 6A/690V A...
View full detailsGVAN11 - TeSys GV2 & GV3 - auxiliary contact block - 1 NO + 1 NC
Schneider ElectricTeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO+1NC instantaneous auxiliary contacts. Rated for operation up to 6A/69...
View full detailsTeSys GV2 & GV3 - auxiliary contact - 1 NO + 1 NC
Schneider ElectricTeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO+1NC instantaneous auxiliary contacts. Rated for operation up to 2A/24...
View full details